Avaliação da radiopacidade dos cimentos MTA Angelus® branco, MTA repair HP, biodentine® e BIO C repair por meio de radiografia digital
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
The satisfactory radiopacity of anendodontic sealer is na important property that hás
already been observed in cements derived from CP, White MTA and MTA Repair.
However, endodontics is constantly evolving, and new cements are being developed
to replace MTA, with similar properties, but with low erradiopacity. Through digital
radiography, the objective of this study was to analyze the radiopacity of the
endodontic sealers MTA Branco, MTA Repair HP, BiodentineandBio C Repair,
comparing them with the dental structures. For the evaluation of the radiopacity of
the cements MTA ANGELUS® White, MTA REPAIR HP, Biodentine and Bio C
Repaire last omermatrices, 2 mm high and with a central opening of 4 mm in
diameter, were used to make Five specimens of each material to be studied. A sound
human lower molar tooth was used in order to compare the radiopacity of the
materials with enameland dentin. The radiographs were take nusing the periapical Xray apparatus Dabi Atlante (Brazil), with Constant exposure time and the focus-film
distance set at 40 cm, providing a perpendicular incidence. In each evaluated
structure, an ROI and mean, standard deviation, minimum and maximum values
were determined. The optical densities of the tested cements, enamel, dentin and
steps of the density scale were presente dusing means, standard deviations and
medians. To assess the normality of radiopacity values, the Shapiro-Wilk test was
applied. To compare the radiopacities of the three cements tested, the Kruskal-Wallis
test and Dunn's post-hoc test were used. The SPSS program (Statistical Package for
the Social Sciences, version 21.0, Chicago, USA) was used, with a significance level
of 5% (p ≤ 0.05). The present study indicated BIO-C and MTA B with high
erradiopacity values when compared to MTA HP and Biodentine, with the former
presenting similar and satisfactory radiopacity values, while biodentine did not reach
values considered sufficient for radiopacity in radiographs digital. It is concluded that
Bio-Cis a possiblesubstitute for MTA, requiring further studies on its physico-chemical
properties.
Description
Keywords
Citation
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto