Comportamento físico-químico e densidade radiográfica de cimentos endodônticos biocerâmicos contemporâneos após imersão em água
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
Abstract
The aim of this study was to evaluate the physicochemical properties of different
bioceramic cements applied in endodontics. This in vitro observational study included
MTA Repair HP, MTA Angelus®, Bio-C® Repair, MTA Fillapex, Bio-C® Sealer,
Biodentine™, CIMMO HD, CIMMO HP, and CIMMO DTA. Ten standardized
specimens (4 mm × 1 mm) were prepared for each material using a Teflon split matrix,
compressed to avoid bubbles, and with thickness checked. One specimen of each
material was subjected to thermal analysis, while the remaining nine were randomly
assigned to three immersion periods in deionized water (24 h, 7 days, and 30 days; n
= 3). Radiopacity was evaluated using a semi-direct digital system with photostimulable
phosphor (PSP) plates and compared with human enamel, dentin, and an aluminum
scale. Solubility was determined as relative mass variation, while pH and electrical
conductivity were measured in the storage solution at each time point. Thermal
behavior was analyzed using simultaneous thermogravimetric and differential thermal
analysis (TG/DTA). Radiopacity remained stable during immersion periods, with MTA
Angelus® and Bio-C® Sealer showing the highest values, while CIMMO HD and
Biodentine™ remained below 3 mm Al. All cements induced an alkaline environment,
with Biodentine™ and MTA Angelus® reaching maximum pH at 30 days (12.31 and
11.59, respectively) and Bio-C® Sealer peaking at 7 days (11.53) before decreasing.
Electrical conductivity increased over time for most materials, with Biodentine™
showing the highest values (1451.60 µS/cm at 30 days). The materials MTA Fillapex®,
MTA Repair HP, Bio-C® Repair, and Bio-C® Sealer lost mass in 7 days, stabilizing in
30 days; Biodentine™ showed a reduction in 30 days. Thermal analysis revealed that
MTA Repair HP and Bio-C® Repair were the most thermally stable (residual mass of
89.46% and 87.07%), while MTA Fillapex® and Bio-C® Sealer decomposed more
extensively (56.37% and 67.70%). It is concluded that the tested bioceramic
endodontic cements presented distinct physicochemical behaviors that can directly
influence their clinical performance. Radiopacity, solubility, pH, ionic release, and
thermal stability varied among the materials, highlighting that no single cement stands
out in all properties.These findings highlight the need for an individualized evaluation
in the selection of bioceramic cements for specific endodontic applications.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Embargado

