Influência do afastamento labial na avaliação tomográfica dos tecidos ósseo e gengival da maxila anterior
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora
DOI
Abstract
The aim of this study was to evaluate the thickness of the buccal bone and the gingival
tissue in the region of upper incisors by using computed tomography cone beam
(CBCT), obtained with or without lip retractor. This is a clinical-tomographic study, in
which the thickness of the buccal bone and gingiva were collected from 120 upper
incisors. Bone and gingival thickness, with and without lip retractor, were measured in
different regions of CBCT images. To validate the use of CBCT for measuring gingival
tissue, the tomographic measurements were correlated with data acquired by clinical
probing. The images with or without lip retractor were also compared regarding their
quality. The bone thickness measurement located at the cervical portion (1 mm above
the bone crest), was higher when lip retractor was employed (paired t-test/ p = 0.021).
The thicknesses of the bone tissue were significantly correlated with those of the
gingival tissue (Pearson correlation/ p ≤ 0.02). The gingival tissue could only be
measured in CBCT scans obtained with lip retractor. The gingival thickness from CBCT
showed significant correlations with those obtained clinically (Pearson correlation/ p ≤
0.001). Regarding the preference of the evaluators, 76% of radiologists and 56% of
implant specialists preferred the images obtained with the lip retractor. It was
concluded that in addition to the classical bone tissue examination, the use CBCT with
lip retractor is a simple and reliable technique for measuring the gingival tissues.
Description
Citation
Collections
Endorsement
Review
Supplemented By
Referenced By
Rights and licensing
Acesso Aberto