Abstract
The generation of electrocardiograms (ECGs) from personalized computational
models has emerged as a promising tool for investigating cardiac electrophysiology. However,
its accuracy critically depends on the correct placement of electrodes on the patient's
torso. This work presents the development of a new software tool for mannal electrode
positioning on patient-specific models and performs a comparative evaluation between this
approach and an automatic method based on deformable registration and statistical torso
models. Four patients with magnetic resonance imaging (MRI) data were analyzed, one
of whom also had computed tomography (CT) imaging, enabling the realistic inclusion
of bony structures. For each patient, the positions of the precordial electrodes were
obtained using both methods, and pseudo-ECGs were subsequently simulated using the
MonoAlg3D cardiac simulator. Quantitative evaluation included the spatial distance
between corresponding electrodes, the Pearson correlation coefficient (PCC), and the
relative root mean square error (rRMSE) between the simulated signals. The results
indicate that electrodes V1-V4 exhibit small spatial discrepancies between methods,
whereas V5 and V6 show larger variations, reaching up to 8em in some patients. Despite
these geometric differences, the pseudo-ECGs maintained a high degree of morphological
similarity, with PCC values frequently exceeding 0.999. The most relevant differences
were observed in signal amplitude, reflected by higher rRMSE values in the lateral leads,
highlighting the increased sensitivity of these regions to electrode positioning errors. The
inclusion of CT data reduced geometric uncertainties and yielded the most consistent
signals between methods, emphasizing the importance of combining multiple imaging
modalities to construct higher-fidelity digital cardiac twins. Study limitations include
the lack of a complete body field of view for marking limb leads, the low resolution of
MRI data for accurate bone segmentation, and the small sample size. Nevertheless, the
results demonstrate that both approaches produce clinically coherent pseudo-ECGs, while
underscoring the need for improved geometric precision in lateral regions and validation in
a larger cohort. Future work will focus on incorporating additional imaging modalities,
validating electrode positions against real ECG recordings, and investigating the impact
of these positioning errors on the electrocardiographic inverse problem.