Uso de eletrodos impressos para análise do teor alcoólico em cachaças e metais pesados em leite

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Universidade Federal de Juiz de Fora (UFJF)

DOI

Abstract

The use of disposable screen-printed electrodes has been growing in recent years as growing demand for environmental analysis, pharmaceutical and industrial products that require quick results and often require the analysis “in situ” samples. In this sense the application of electroanalytical techniques using screen-printed electrodes stands out for easy of transport, handling, rapid and low cost compared to other traditional methods of analysis. In this study copper and gold screen-printed electrodes were produced from a conductive plate of copper and a compact disc (CD) recordable gold and applied to analysis of samples of cachaça and milk, respectively. Copper screen-printed electrode was used to measure the ethanol content in cachaças from Minas Gerais, by cyclic voltammetry and amperometry, without any pretreatment of the sample. Analyses were performed using NaOH 1,0 mol L-1 as supporting electrolyte, which also played an important role in the activation of the electrode. The results obtained by both techniques had a strong correlation, and were compared with the alcohol content expressed on the labels and with results obtained using a digital densimeter used to determine the alcohol content in distilleries. Voltammetric and amperometric techniques obtained detection limits of 0,024% v / v and 0,085% v / v, respectively. Gold screen-printed electrode was used in the determination of lead and copper in samples of processed milk. Milk samples were completely carbonized at 500°C, a process aided by adding HNO3 and H2O2 (30% w/v), and subsequently dissolved in HCl supporting electrolyte 0,10 mol L-1. Thus the concentration of Pb2+ and Cu2+ were determined by anodic stripping voltammetric, and parameters such as time of deposition and deposition potential were optimized for the gold screen-printed electrodes. The limits of detection for the determination of copper and lead were 0.60 and 0.80 mg L-1, using 120 s as deposition time and -500 mV as deposition potential. The lead concentrations ranged between 50 and 411 µg L-1, values above those permitted by Brazilian law, while copper concentrations ranged between 44 and 299 µg L-1, with two samples exceeding the maximum allowed.

Description

Citation

Endorsement

Review

Supplemented By

Referenced By

Rights and licensing

Acesso Aberto