O tratamento da superfície do implante buscando a otimização da osseointegração: uma revisão de literatura
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal de Juiz de Fora (UFJF)
DOI
Abstract
Osseointegration consists of an anchoring mechanism in which non-vital components can be
reliably incorporated into living bone. This phenomenon does not derive from an advantageous
biological response, but from the lack of a negative tissue response. Some physical-chemical
components alter the response of bone metabolism, which can modify the time of total recovery as
well as the quality and quantity of bone deposited. Roughness stands out because this characteristic
influences the behavior of osteoprecursor cells, stimulating proliferation and inducing osteoblast
differentiation. Furthermore, the conventional protocol for loading the implant lasts from 0 to 9
months, which is not ideal in areas where aesthetic rigor is greater. Thus, research on surfaces that
have greater osteoconductive capacity, reducing restoration time and maintaining long-term
success rates, has intensified. The aim of this study was to review the various methods of implant
surface treatment to understand their benefits for osseointegration and their biological effects. The
following types of modification were addressed: machining, plasma spray, sandblasting, laser
beam modification, acid etching, sandblasting with acid etching, anodizing, hydrophilic surfaces,
and biomimetic coatings.