Abstract
Structural vibration control systems are means of protection which aim the reduction
of excessive or undesirable vibrations caused by dynamic loads on civil structures in other
to assure safety and comfort criteria. Those systems are classified into passive, active,
hybrid and semi-active. Semi-active controls systems are among the most used due to
reliability and simplicity reasons. The magnetorheological dampers (MR) are semi-active
devices capable of changing from liquid to semisolid state in milliseconds, in a reversible
manner, when exposed to a magnetic field. Due to this capability, MR dampers are considered
as a perfect tool for controlling structural systems - allowing the management of
damping load fast and safely, with small amount of energy. This work studies the efficiency
of semi-active control systems, by means of MR dampers applied to a two-story building
model subject to accelerations applied to its basis. The obtained results are compared
to data available in the literature, showing good agreement. The adopted methodology
consists in evaluating the MR dampers behavior in three distinct situations: 1) applied
as a passive damper: under constant voltage, with no variation of dampers properties; 2)
applied as a semiactive controller for which the activation voltage is determined by the
clipped optimal algorithm based on a linear quadratic regulator - with voltages of 0V or a
maximum value; 3) applied as a semiactive controller with optimized activation voltage,
assuming voltage values ranging from 0V to a maximum value. This strategy is original
and consists in the main contribution of the present work. For comparison purposes, the
studied model was also subjected to purely active control, by assuming a mechanical actuator
exerting control forces directly on the structure. This strategy allows confronting
the performance of the MR damper with an active controller.