This study evaluated treatment strategies for sludge generated in drinking water treatment
plants (DWTPs), with emphasis on the application of the Fenton process using the sludge itself as an iron source, aiming at the reduction of the microbiological load and the improvement of sedimentability. The sludge was collected from a full-cycle WTP located in the Zona da Mata region of Minas Gerais, Brazil, and characterized in terms of physical, chemical, and microbiological parameters. The experiments were conducted at bench scale, with pH adjustment and different molar ratios of Fe:H2O2, in addition to complementary tests with pH variation only. Sedimentability was assessed through settling velocity tests, and microbiological efficiency was evaluated using indicators such as Escherichia coli and aerobic endospores (AE). The results demonstrated that the Fenton process promoted effective microbiological inactivation, with the absence of Escherichia coli under the condition of pH 5 and Fe:H2O2 = 1:1, while AE showed greater resistance, being mainly removed by physical mechanisms associated with sedimentation. A significant improvement in settling behavior and solid–liquid separation was also observed, highlighting the potential of the process as a sustainable alternative for DWTP sludge management.