https://repositorio.ufjf.br/jspui/handle/ufjf/21484| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| gabrielpinheirolacerda.pdf | 5.59 MB | Adobe PDF | Visualizar/Abrir |
| Clase: | Tese |
| Título : | Influência do pré-aquecimento do cimento resinoso em pinos de fibra de vidro anatomizados e fresados (CAD/CAM) em canais ovais: análise por micro-CT e resistência à compressão |
| Autor(es): | Lacerda, Gabriel Pinheiro |
| Orientador: | Laxe, Laísa Araújo Cortines |
| Miembros Examinadores: | Carvalho, Ronaldo Luís Almeida de |
| Miembros Examinadores: | Lima, Carolina Oliveira de |
| Miembros Examinadores: | Oliveira, Felipe Eduardo de |
| Miembros Examinadores: | Carlo, Hugo Lemes |
| Resumo: | Canais radiculares ovais desafiam a adaptação convencional de pinos de fibra, comprometendo a homogeneidade da interface de cimentação. O reembasamento anatômico manual e a fresagem via CAD/CAM (projeto e fabricação assistidos por computador) foram propostos para melhorar o ajuste do pino ao canal, enquanto o pré-aquecimento do cimento resinoso pode modular o escoamento e a polimerização. Este estudo avaliou os efeitos da estratégia de personalização do pino de fibra (reembasamento anatômico manual versus fresagem CAD/CAM) e do préaquecimento do cimento resinoso autoadesivo (22°C versus 69°C) no volume de vazios na interface e na resistência à fratura em canais radiculares ovais. Trinta e seis pré-molares superiores humanos com canais ovais (razão vestíbulo-lingual/mesiodistal ≥ 2:1) foram pareados por meio de microtomografia computadorizada (microCT) e distribuídos em quatro grupos (n = 9) em um delineamento fatorial 2 × 2. Os espécimes foram cimentados, escaneados por micro-CT para quantificação de vazios, restaurados com coroas fresadas, submetidos a envelhecimento termomecânico e testados sob compressão oblíqua (135°; 0,5 mm/min) até a falha. Foram aplicadas a análise de variância de dois fatores (α = 0,05) e a correlação de Pearson. Ambos os fatores afetaram significativamente o volume de vazios e a resistência à fratura, sem interação significativa. Pinos personalizados anatomicamente apresentaram menor porcentagem de vazios e maior resistência à fratura do que pinos fresados via CAD/CAM. O pré-aquecimento a 69°C aumentou os vazios na interface e reduziu a resistência à fratura, independentemente do tipo de pino. Observou-se uma correlação negativa significativa entre o volume de vazios e a carga de fratura. A personalização anatômica manual melhorou a integridade da interface de cimentação e a resistência à fratura em canais radiculares ovais. O pré-aquecimento a 69°C prejudicou ambos os parâmetros de forma independente |
| Resumen : | Oval root canals challenge conventional fiber post adaptation, compromising cementation interface homogeneity. Manual anatomical relining and computer-aided design/computer-aided manufacturing (CAD/CAM) milling have been proposed to improve post-to-canal fit, while resin cement preheating may modulate flow and polymerization. This study evaluated the effects of fiber post customization strategy (manual anatomical relining vs. CAD/CAM milling) and self-adhesive resin cement preheating (22°C vs. 69°C) on interfacial void volume and fracture resistance in oval root canals. Thirty-six human maxillary premolars with oval canals (buccolingual/mesio-distal ratio ≥ 2:1) were matched by micro-computed tomography (microCT) and allocated to four groups (n = 9) in a 2 × 2 factorial design. Specimens were cemented, scanned by micro-CT for void quantification, restored with milled crowns, subjected to thermo-mechanical aging, and loaded under oblique compression (135°; 0.5 mm/min) until failure. Two-way analysis of variance (α = 0.05) and Pearson correlation were applied. Both factors significantly affected void volume and fracture resistance, with no significant interaction. Anatomically customized posts yielded lower void percentage and higher fracture resistance than CAD/CAM-milled posts. Preheating to 69°C increased interfacial voids and reduced fracture resistance regardless of post type. A significant negative correlation was observed between void volume and fracture load. Manual anatomical customization improved cementation interface integrity and fracture resistance in oval root canals. Preheating to 69°C impaired both parameters independently. |
| Palabras clave : | Técnica para retentor intrarradicular Fraturas dos dentes Microtomografia por raio-X Post and core technique Tooth fractures X-ray microtomography |
| CNPq: | CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA |
| Idioma: | por |
| País: | Brasil |
| Editorial : | Universidade Federal de Juiz de Fora (UFJF) |
| Sigla de la Instituición: | UFJF |
| Departamento: | Faculdade de Odontologia |
| Programa: | Programa de Pós-graduação em Clínica Odontológica |
| Clase de Acesso: | Acesso Aberto Attribution-NonCommercial-NoDerivs 3.0 Brazil |
| Licenças Creative Commons: | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ |
| URI : | https://repositorio.ufjf.br/jspui/handle/ufjf/21484 |
| Fecha de publicación : | 28-sep-2026 |
| Aparece en las colecciones: | Doutorado em Odontologia (Teses) |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons